FASTASeq S Ultra-High-Speed Sequencer GeneMind

GeneMind
#fastaseq-s

FASTASeq S is designed for laboratories that need rapid sequencing turnaround from library preparation to data output. The platform combines a high-speed fluidic system, updated enzyme chemistry and AI-powered base calling to improve cycle efficiency while maintaining high-quality output from low-input samples.

Key advantages

  • Listed output timing includes 2.0 hours for SE50, 3.0 hours for SE100 and 6.8 hours for PE150 on FCL flow cells
  • Run preparation can be completed in about 7 minutes
  • Reduced reagent consumption for sequencing-on-demand workflows
  • Supports flow cell surface amplification for nanogram-level trace samples
  • Smart waste sorting and load-and-go reagent handling

For Research Use Only. Not intended for diagnostic or clinical procedures. Availability may vary by country.

Type: Sequencing system

Section: Sequencers

lwh: 626x580x575 mm

Weight: 100000 g

Product Advantages
Specification
Run Modes
Application Capacity

Product Advantages

AdvantageDetails
Swift2.0 hr SE50, 3.0 hr SE100 and 6.8 hr PE150 listed run times; lightning chemistry reduces cycle time by 50%.
SimpleUser-friendly interface and about 7 minutes of NGS run preparation.
SavingReduces reagent consumption by 70% and supports sequencing on demand.
Social ResponsibleSmart waste sorting and processing design; room-temperature shipping and storage for load-and-go reagent.

Specification

ParameterValue
Flow cell optionsFCL, FCM, FCX, FCH
Fastest listed runSE50 in about 2.0 hours
Maximum listed output24 Gb with FCH PE150 or FCX PE300
Dimensions (W x D x H)626 mm x 580 mm x 575 mm
WeightAbout 100 kg
Power requirements<= 1000 VA; 200-240 V, 50/60 Hz</td>
Operating environment19-30 deg C; 20-80% RH, non-condensing; altitude <= 3000 m</td>
Control computerIntel Core i7-13700T; 64 GB memory; 4 TB hard drive; Windows 10

Run Modes

Flow cellLaneReads/FCSpecificationRead lengthOutputQ30TAT
FCL120MSE100-DSE501 Gb>=90%~2.0 hr
FCL120MSE100-DSE1002 Gb>=90%~3.0 hr
FCL120M100 cyclesPE502 Gb>=90%~4.0 hr
FCL120M300 cyclesPE1506 Gb>=90%~6.8 hr
FCL120M400 cyclesSE4008 Gb>=80%~16 hr
FCM140MSE100-DSE502 Gb>=90%~2.5 hr
FCM140M300 cyclesPE15012 Gb>=90%~7.5 hr
FCX140M600 cyclesPE30024 Gb>=85%~24 hr
FCH180MSE100-DSE504 Gb>=90%~3.5 hr
FCH180M300 cyclesPE15024 Gb>=90%~12 hr

Application Capacity

ApplicationRead lengthData per sampleFCL 20MFCM/FCX 40MFCH 80M
mNGS, probe captureSE500.5M reads/sample204080
Microbial WGSPE1501 Gb/sample61224
16S amplicon sequencingPE30050-100K reads/sample/200-400/
Shallow shotgun metagenomicsPE1504M reads/sample51020
TB-tNGSPE1002M reads/sample51020
Carrier screeningPE1501.2 Gb/sample102040
HLA typingPE1500.6 Gb/sample204080
NGS library QCSE1000.1 Gb/sample60120240